Cole Walker f2542a59f1 Update default ptp4lClockClassLockedList values
In order to better support the default configuration when
ptp-notification is deployed on a BC, the ptp4lClockClassLockedList
values should in include 135 as a locked clockClass.

This change ensures that classes 6, 7 and 135 are considered acceptable
for the ptp-notification locked state by default, with the ability to
override the acceptable clockClasses available to the user.

Test plan:
PASS: Build ptp-notification helm charts
PASS: Deploy ptp-notification
PASS: v1 api - test ptp4lClockClassLockedList with the default list
PASS: v2 api - test ptp4lClockClassLockedList with the default list

Partial-bug: 2033539

Signed-off-by: Cole Walker <cole.walker@windriver.com>
Change-Id: Ic569c373dc2ddf1771e83b12832ef1460266c93a