Adding semantic check on platform-integ-apps reapply operation
The reapply operation needs to do the same checks done on the apply operation. These checks prevent reapplying the application on some ceph or system scenarios. Moreover, on the method pre_auto_apply_check, it is possible that conductor_object._ceph (CephOperator) is not initialized yet, and trying to access its methods will raise an AttributeError exception. As this is a possible scenario, this case is now tested, and a LifecycleSemanticCheckException is raised. Test Plan: PASS: (AIO-DX) Check that platform-integ-apps is on uploaded state PASS: (AIO-DX) Unmanage ceph-mon PASS: (AIO-DX) Stop ceph-mon service PASS: (AIO-DX) Restart sysinv-conductor service PASS: (AIO-DX) Check on sysinv logs that the new Exception is being logged and the platform-integ-apps still trying to be applied PASS: (AIO-DX) Manage ceph-mon PASS: (AIO-DX) Start ceph-mon service PASS: (AIO-DX) After the Ceph cluster has become responsive, check that platform-integ-apps is being successfully applied. PASS: (AIO-DX) Check that platform-integ-apps is on applied state PASS: (AIO-DX) Unmanage ceph-mon PASS: (AIO-DX) Stop ceph-mon service PASS: (AIO-DX) Restart sysinv-conductor service PASS: (AIO-DX) Check on sysinv logs that the new Exception is being logged and the platform-integ-apps still trying to be applied. PASS: (AIO-DX) Wait until platform-integ-apps is on apply-failed state Closes-bug: 2052315 Change-Id: I8c3318cc6f002671cb2e4bf81b14238ac4467131 Signed-off-by: Guilherme Costa <guilherme.costa@windriver.com>
This commit is contained in:
parent
5d3806316f
commit
788991a76d
@ -38,7 +38,8 @@ class PlatformAppLifecycleOperator(base.AppLifecycleOperator):
|
||||
# Semantic checks
|
||||
if hook_info.lifecycle_type == constants.APP_LIFECYCLE_TYPE_SEMANTIC_CHECK:
|
||||
if hook_info.mode == constants.APP_LIFECYCLE_MODE_AUTO and \
|
||||
hook_info.operation == constants.APP_APPLY_OP and \
|
||||
hook_info.operation in [constants.APP_APPLY_OP,
|
||||
constants.APP_EVALUATE_REAPPLY_OP] and \
|
||||
hook_info.relative_timing == constants.APP_LIFECYCLE_TIMING_PRE:
|
||||
return self.pre_auto_apply_check(conductor_obj)
|
||||
|
||||
@ -83,6 +84,12 @@ class PlatformAppLifecycleOperator(base.AppLifecycleOperator):
|
||||
if not os.path.isfile(crushmap_flag_file):
|
||||
raise exception.LifecycleSemanticCheckException(
|
||||
"Crush map not applied")
|
||||
# conductor_obj._ceph (CephOperator) may not be initialized
|
||||
# at this point, as it depends on ceph and system conditions
|
||||
# to start the thread that initializes it
|
||||
if conductor_obj._ceph is None:
|
||||
raise exception.LifecycleSemanticCheckException(
|
||||
"CephOperator is not initialized yet")
|
||||
if not conductor_obj._ceph.have_ceph_monitor_access():
|
||||
raise exception.LifecycleSemanticCheckException(
|
||||
"Monitor access error")
|
||||
|