Artom Lifshitz bee34dbb86 Wait for libvirt domain shutdown correctly
Previousy, when shutting down a libvirt domain before evacuation, we
would wait until it disappeared from the list of libvirt domains, but
we just merrily continued on even if it was still present after 60
seconds. I suspect the domain remained present, and our next steps
were to evacuate the instance and start nova-compute back up again, at
which point it tried to delete evacuated instances, and fail with the
following:

File "/opt/stack/nova/nova/compute/manager.py", line 839, in _destroy_evacuated_instances
<snip>
libvirt.libvirtError: Failed to terminate process 55183 with SIGKILL: Device or resource busy

This patch makes us wait for the domain to disappear, and raise an
error if it doesn't disappear in time. It also refactors the shutdown
code slightly to avoid an extra API quey to get the server.

Change-Id: I76885987842440f9b690c198e6b8149bdd85f899
2024-11-19 14:36:54 -05:00

251 lines
8.9 KiB
Python

# Copyright 2020 Red Hat Inc.
# All Rights Reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
from tempest.common import waiters
from tempest import config
from whitebox_tempest_plugin.api.compute import base
from whitebox_tempest_plugin.services import clients
from oslo_log import log as logging
CONF = config.CONF
LOG = logging.getLogger(__name__)
class VDPASmokeTests(base.BaseWhiteboxComputeTest):
@classmethod
def skip_checks(cls):
super(VDPASmokeTests, cls).skip_checks()
if getattr(CONF.whitebox_hardware,
'vdpa_physnet', None) is None:
raise cls.skipException('Requires vdpa_physnet parameter '
'to be set in order to execute test '
'cases.')
if getattr(CONF.whitebox_hardware,
'vdpa_vlan_id', None) is None:
raise cls.skipException('Requires '
'vdpa_vlan_id parameter to be set in '
'order to execute test cases.')
def setUp(self):
super(VDPASmokeTests, self).setUp()
self.vlan_id = \
CONF.whitebox_hardware.vdpa_vlan_id
self.physical_net = CONF.whitebox_hardware.vdpa_physnet
self.network = self._create_net_from_physical_network(
self.vlan_id,
self.physical_net)
self._create_subnet(self.network['network']['id'])
def test_guest_creation_with_vdpa_port(self):
"""Creates a guest that requires a vdpa port"""
flavor = self.create_flavor()
port = self._create_port_from_vnic_type(
net=self.network,
vnic_type='vdpa'
)
server = self.create_test_server(
flavor=flavor['id'],
networks=[{'port': port['port']['id']}],
wait_until='ACTIVE'
)
interface_xml_element = self._get_xml_interface_device(
server['id'],
port['port']['id'],
)
if CONF.whitebox.rx_queue_size:
driver = interface_xml_element.find("./driver[@name='vhost']")
self.assertEqual(
str(CONF.whitebox.rx_queue_size),
driver.attrib['rx_queue_size'],
"VDPA rx_queue_size equaling %s not found" %
str(CONF.whitebox.rx_queue_size))
# Confirm dev_type, allocation status, and pci address information are
# correct in pci_devices table of openstack DB
self._verify_neutron_port_binding(
server['id'],
port['port']['id']
)
class VDPAColdMigration(VDPASmokeTests):
@classmethod
def skip_checks(cls):
super(VDPAColdMigration, cls).skip_checks()
if CONF.compute.min_compute_nodes < 2:
msg = "Need two or more compute nodes to execute cold migration"
raise cls.skipException(msg)
if not CONF.compute_feature_enabled.vdpa_cold_migration_supported:
msg = "vDPA Cold Migration support needed in order to run tests"
raise cls.skipException(msg)
def _test_vdpa_cold_migration(self, revert=False):
port = self._create_port_from_vnic_type(
net=self.network,
vnic_type='vdpa'
)
server = self.create_test_server(
networks=[{'port': port['port']['id']}],
wait_until='ACTIVE'
)
# Determine a target host for cold migration target
dest_host = self.get_host_other_than(server['id'])
# Cold migrate the the instance to the target host
src_host = self.get_host_for_server(server['id'])
self.admin_servers_client.migrate_server(server['id'], host=dest_host)
waiters.wait_for_server_status(self.servers_client, server['id'],
'VERIFY_RESIZE')
if revert:
self.admin_servers_client.revert_resize_server(server['id'])
else:
self.admin_servers_client.confirm_resize_server(server['id'])
waiters.wait_for_server_status(self.servers_client,
server['id'], 'ACTIVE')
dest_host = self.get_host_for_server(server['id'])
# If the cold migration is reverted the guest should be back on
# it's original host. Otherwise the destination host should now be
# different from the source
if revert:
self.assertEqual(src_host, dest_host)
else:
self.assertNotEqual(src_host, dest_host)
interface_xml_element = self._get_xml_interface_device(
server['id'],
port['port']['id'],
)
if CONF.whitebox.rx_queue_size:
driver = interface_xml_element.find("./driver[@name='vhost']")
self.assertEqual(
str(CONF.whitebox.rx_queue_size),
driver.attrib['rx_queue_size'],
"VDPA rx_queue_size equaling %s not found" %
str(CONF.whitebox.rx_queue_size))
# Confirm dev_type, allocation status, and pci address information are
# correct in pci_devices table of openstack DB
self._verify_neutron_port_binding(
server['id'],
port['port']['id']
)
def test_vdpa_cold_migration(self):
self._test_vdpa_cold_migration()
def test_revert_vdpa_cold_migration(self):
self._test_vdpa_cold_migration(revert=True)
class VDPAResizeInstance(VDPASmokeTests):
@classmethod
def skip_checks(cls):
super(VDPAResizeInstance, cls).skip_checks()
if not CONF.compute_feature_enabled.vdpa_cold_migration_supported:
msg = "vDPA Cold Migration support needed in order to run " \
"resize tests"
raise cls.skipException(msg)
if not CONF.compute_feature_enabled.resize:
msg = 'Resize not available.'
raise cls.skipException(msg)
def setUp(self):
super(VDPAResizeInstance, self).setUp()
self.new_flavor = self.create_flavor(vcpus=2, ram=256)
def test_vdpa_to_standard_resize(self):
# Create an instance with a vDPA port and resize the server
port = self._create_port_from_vnic_type(
net=self.network,
vnic_type='vdpa'
)
server = self.create_test_server(
networks=[{'port': port['port']['id']}],
wait_until='ACTIVE'
)
self.resize_server(server['id'], self.new_flavor['id'])
interface_xml_element = self._get_xml_interface_device(
server['id'],
port['port']['id'],
)
if CONF.whitebox.rx_queue_size:
driver = interface_xml_element.find("./driver[@name='vhost']")
self.assertEqual(
str(CONF.whitebox.rx_queue_size),
driver.attrib['rx_queue_size'],
"VDPA rx_queue_size equaling %s not found" %
str(CONF.whitebox.rx_queue_size))
# Confirm dev_type, allocation status, and pci address information are
# correct in pci_devices table of openstack DB
self._verify_neutron_port_binding(
server['id'],
port['port']['id']
)
class VDPAEvacuateInstance(VDPASmokeTests):
min_microversion = '2.95'
@classmethod
def skip_checks(cls):
super(VDPAEvacuateInstance, cls).skip_checks()
if CONF.compute.min_compute_nodes < 2:
msg = "Need two or more compute nodes to execute evacuate."
raise cls.skipException(msg)
def test_evacuate_server_vdpa(self):
# Create an instance with a vDPA port and evacuate
port = self._create_port_from_vnic_type(
net=self.network,
vnic_type='vdpa'
)
server = self.create_test_server(
networks=[{'port': port['port']['id']}],
wait_until='ACTIVE'
)
server_id = server['id']
host_a = self.get_host_for_server(server_id)
host_a_svc = clients.NovaServiceManager(
host_a, 'nova-compute', self.os_admin.services_client)
with host_a_svc.stopped():
self.shutdown_server_domain(server, host_a)
self.evacuate_server(server_id)
self.assertNotEqual(self.get_host_for_server(server_id), host_a)
# Confirm dev_type, allocation status, and pci address information are
# correct in pci_devices table of openstack DB
self._verify_neutron_port_binding(
server_id,