Doc improvements
Improve dbreco.rst based on suggestions from eglynn Add remark about availability of compute meters in measurements.rst Change-Id: I42cc3fe27cd9dab97c6c2353326c69577eb0f7cd
This commit is contained in:
parent
cb7362ed04
commit
f90b36d745
@ -21,20 +21,20 @@ Selecting a database backend for Ceilometer should not be done lightly for
|
|||||||
numerous reasons:
|
numerous reasons:
|
||||||
|
|
||||||
1. Not all backend drivers are equally implemented and tested. To help you
|
1. Not all backend drivers are equally implemented and tested. To help you
|
||||||
make your choice, the below indications will give you some idea of the
|
make your choice, the table below will give you some idea of the
|
||||||
status of each of the drivers available in trunk. Note that we do welcome
|
status of each of the drivers available in trunk. Note that we do welcome
|
||||||
patches to improve completeness and quality of drivers.
|
patches to improve completeness and quality of drivers.
|
||||||
|
|
||||||
2. It may not be a good idea to use the same host as another database as
|
2. It may not be a good idea to use the same host as another database as
|
||||||
Ceilometer can generate a LOT OF WRITES. For this reason it is generally
|
Ceilometer can generate a LOT OF WRITES. For this reason it is generally
|
||||||
recommended, if the deployement is targeting going into production, to use
|
recommended, if the deployment is targeting going into production, to use
|
||||||
a dedicated host, or at least a VM which will be migratable to another
|
a dedicated host, or at least a VM which will be migratable to another
|
||||||
physical host if needed. The following spreadsheet can help you get an
|
physical host if needed. The following spreadsheet can help you get an
|
||||||
idea of the volumes that ceilometer can generate:
|
idea of the volumes that ceilometer can generate:
|
||||||
`Google spreadsheet <https://docs.google.com/a/enovance.com/spreadsheet/ccc?key=0AtziNGvs-uPudDhRbEJJOHFXV3d0ZGc1WE9NLTVPX0E#gid=0>`_
|
`Google spreadsheet <https://docs.google.com/a/enovance.com/spreadsheet/ccc?key=0AtziNGvs-uPudDhRbEJJOHFXV3d0ZGc1WE9NLTVPX0E#gid=0>`_
|
||||||
|
|
||||||
3. If you are relying on this backend to bill customers, you will note that
|
3. If you are relying on this backend to bill customers, you will note that
|
||||||
its reliability is very much linked to your capacity to generate revenue,
|
your capacity to generate revenue is very much linked to its reliability,
|
||||||
which seems to be a factor dear to many managers.
|
which seems to be a factor dear to many managers.
|
||||||
|
|
||||||
The following is a table indicating the status of each database drivers:
|
The following is a table indicating the status of each database drivers:
|
||||||
|
@ -85,6 +85,11 @@ network.outgoing.packets Cumulative packets iface ID pollster number o
|
|||||||
|
|
||||||
======================== ========== ======== ======== ============ =======================================================
|
======================== ========== ======== ======== ============ =======================================================
|
||||||
|
|
||||||
|
At present, most of the Nova meters will only work with libvirt front-end
|
||||||
|
hypervisors while test coverage was mostly done based on KVM. Contributors
|
||||||
|
are welcome to implement other virtualization backends’ meters or complete
|
||||||
|
the existing ones.
|
||||||
|
|
||||||
Network (Quantum)
|
Network (Quantum)
|
||||||
=================
|
=================
|
||||||
|
|
||||||
|